Technical data
- Rated supply voltage 220 â 240 V
- Input voltage, AC 198 â 264 V
- Input voltage, DC 176 â 280 V
- Mains frequency 0 / 50 / 60 Hz
- Overvoltage protection 320 V AC, 48 h
- current (at 230 V, 50 Hz, full load)1 2 65 â 95 mA
- current (220 V, 0 Hz, full load, 15 %
- dimming level)2 15 â 25 mA
- Leakage current (at 230 V, 50 Hz, full load)1 2 < 700 µA
- input power 22.5 W
- efficiency (at 230 V / 50 Hz / full load)2 86 %
- λ (at 230 V, 50 Hz, full load)1 0.96
- power consumption on stand-by < 0.35 W
- input current in no-load operation 12.3 mA
- input power in no-load operation 0.35 W
- In-rush current (peak / duration) 20 A / 140 µs
- THD (at 230 V, 50 Hz, full load)1 < 3 %
- Starting time (at 230 V, 50 Hz, full load)1 < 0.7 s
- Starting time (DC mode) < 0.4 s
- Switchover time (AC/DC)6 < 0.4 s
- Turn off time (at 230 V, 50 Hz, full load) < 30 ms
- Output current tolerance1 5 ± 3 %
- output current peak (non-repetitive) ⤠output current + 40 %
- Output LF current ripple (< 120 Hz) ± 5 %
- Output PstLM (at full load) ⤠1
- Output SVM (at full load) ⤠0.4
- output voltage (no-load voltage) 60 V
- Dimming range 1 â 100 %
- Mains surge capability (between L â N) 1 kV
- Mains surge capability (between L/N â PE) 2 kV
- Surge voltage at output side (against PE) < 500 V
- Type of protection IP20
- Radio transceiver operating frequencies 2.4 â 2.483 GHz
- output power radio transceiver (E.R.I.P.)7 < +20 dBm
- Lifetime up to 100,000 h
- Guarantee (conditions at www.tridonic.com) 5 years
- Dimensions L x W x H 130 x 43 x 30 mm